This fact sheet will provide an overview of the environmental regulations relevant to Ohio dry cleaners. It will also discuss ways to potentially reduce environmental risk and regulatory burden by reducing the generation of wastes and emissions at the source and through recycling.
Background
Process overview
The dry cleaning industry provides garment and other apparel cleaning services,
and related services such as clothes pressing and finishing. The types of establishments
that make up this industry include:
Retail dry cleaning stores;
Industrial and linen supply plants with dry cleaning operations;
Leather and fur cleaning plants; and
Self-service laundromats with dry cleaning equipment.
Dry cleaners typically use either perchloroethylene (perc, tetrachloroethylene) or petroleum solvents (stoddard, quick-dry, low-odor or 140 F) as cleaning solvents. The dry cleaning process consists of three principal steps: cleaning or washing the garments; extracting used solvent; and "drying" the garment.
In the cleaning stage, garments are pre-treated for stains and then machine washed in a solution of a solvent, soap and detergent. The extraction process, essential for any dry cleaning operation, removes solvents by draining and spinning the clothes. This reduces solvent loss, eliminates waste and dripping of solvents, and reduces the weight of wet garments. The drying process removes any solvent remaining in the garments by tumbling them in a stream of warm air. When the removal of solvents is complete, the clothes often are treated with a stream of fresh air, a process called deodorizing or aerating. Finally, a garment may be finished by pressing or a similar operation.
Four basic types of dry cleaning machinery have evolved over time, each representing a higher level of technology. However, all are still in use today.
| |||||||||
Dry-to-dry: This equipment combines washing and drying in a single machine. Since clothing is no longer transferred to another machine, solvent air emissions are reduced, which in turn reduces solvent use. Some vent residual vapors to the atmosphere or to an external control device. Others, described below, use internal control devices.
Closed loop dry-to-dry with refrigerated condensers: This equipment modifies
the previous equipment by adding control technology, built in refrigerated condensers,
to reduce vapor emissions. These machines do not vent air to the atmosphere,
but recycle it continuously through the dry cleaning cycle.
Closed loop dry-to-dry with additional vapor recovery device: This equipment
modifies the previous equipment by adding additional internal vapor recovery
devices. These machines use refrigerated condensers and carbon adsorbers. These
are the most efficient machines, with the least amount of solvent air emissions,
and subsequently the lowest use of solvent. (U.S. EPA, 1995; Ohio EPA, 1993).
Waste streams
Dry cleaning can be responsible for the generation of hazardous waste, air emissions and wastewater (Figure 1). These wastes and emissions must be managed according to environmental regulations.
Hazardous waste can include materials such as spent solvents, spent carbon and carbon cartridges from carbon adsorbers, still residues from solvent distillation (still bottoms), cooked powder residues (muck) and drums.
Solvent emissions can be directly released into the air during washing, aeration, still and other equipment operation, and door openings at the end of cycles. Fugitive releases can occur during clothes transfer and because of equipment leaks, losses during solvent transfer and evaporation from spent filters and distillation wastes.
The recovery of solvent from vapors routed to water separators from condensers, carbon adsorbers, cartridge strippers, stills and muck cookers can yield water-contaminated solvent. The volume of water is often increased by the water present in the garments that are laundered. The solvent can be recovered in a water separator, however, the water drained from the top of the separator will still be contaminated with solvent. This wastewater is often referred to as separator water. (CIS, no date: U.S. EPA, 1995; Ohio EPA, 1993).
Environmental Regulations
The hazardous waste, air emissions and wastewater generated by dry cleaners can
pose a threat to the environment and to public health and safety. Environmental
regulations have been developed to reduce that risk. Dry cleaning operations
may be subject to regulations for hazardous waste, air emissions, and wastewater,
whether you discharge to a wastewater treatment plant, directly to a body of
water, or to an underground injection well (septic system) or storage tank.
The following sections discuss these environmental regulations. Each section contains a reference for who to contact for more information. Telephone numbers and addresses for these contacts are listed at the end of this document in a section titled, Who to Call.
Hazardous waste
Most dry cleaners generate hazardous waste. Hazardous wastes are classified into
two types: listed and characteristic.
Listed hazardous wastes are listed by name or process in the Code of Federal Regulations Chapter 261, and in Ohio's Hazardous Waste Management Rules, Ohio Administrative Code Chapter 3745-51. For example, perc used in dry cleaning is a listed hazardous waste with a hazardous waste code of F002 when spent. Perc has the waste code U210 as a pure commercial chemical product if discarded prior to use. Spill residues from the cleanup of perc product spills are also considered to be U210 hazardous waste. Any other waste coming in contact with a listed waste also becomes a listed waste by virtue of the "mixture rule." This includes wastes such as filters, filter media, still residue (sludge), and filter powder (muck) containing perc.
A characteristic waste exhibits one or more of the four hazardous characteristics (ignitability, reactivity, corrosivity and toxicity). For example, a waste solvent exhibits the characteristic of ignitability if it has a flashpoint below 140 degrees F.
The characteristic of toxicity is determined by use of the Toxicity Characteristic Leaching Procedure (TCLP). This analytical test simulates the acidic conditions found in a landfill and determines how much of certain regulated substances would leach from the waste if placed in a landfill. Regulatory levels are set for 39 hazardous constituents in terms of parts per million, and any waste exceeding these levels is a toxic hazardous waste. Perc, for example, is one of the 39 hazardous constituents. Any waste which contains 0.7 parts per million or more of perc is considered to be a D039 toxic hazardous waste.
Who is a generator?
Every dry cleaning facility that produces hazardous waste is considered a generator.
What steps are required to properly dispose of hazardous waste?
Step 1: Evaluate the facility's waste
Step 2: Determine the facility's generator status
There are three categories of hazardous waste generators. These categories are
determined by the amount of hazardous waste that is generated by a business each
calendar month. The hazardous waste requirements differ for these three sizes
of generators.
CESQGs are required to:
|
| SQGs must follow steps three through six as detailed below. |
| Most dry cleaners in Ohio are SQGs or CESQGs. LQGs must comply with additional requirements. Additional guidance for LQGs is available by calling Ohio EPA, Division of Hazardous Waste Management at (614) 644-2934. |
Step 3: Comply with hazardous waste accumulation requirements
Hazardous waste must be stored in containers that are:
Step 4: Transportation and disposal of hazardous waste
Use of manifests
A hazardous waste manifest is a shipping form, completed by the generator, that
accompanies each shipment of hazardous waste when it is transported off-site.
Manifests are required of all SQGs and LQGs sending waste off-site. Manifests
are not required for SQGs who are reclaiming their waste under a contractual
agreement if all of the following conditions are met:
All manifest copies must be kept for a period of three years from the date the waste was accepted by the initial transport.
Land Disposal Restrictions (LDRs)
A Land Disposal Restriction (LDR) form must accompany hazardous waste to the
disposal facility. Hazardous waste cannot be landfilled without first meeting
certain treatment standards. An LDR form notifies the disposal facility that
waste meets treatment standards or does not meet treatment standards. An LDR
form must be completed even if the waste is to be recycled. The disposal facility
will treat the waste prior to land disposal, if necessary. The generator must
identify on an LDR form what constituents are present in the waste - this can
be done by generator knowledge and/or analytical testing. All LDR forms must
be kept on file for a period of five years after the date the waste was sent
to the treatment, storage and disposal facility.
Liability
Although a waste disposal or recycling firm is often hired to manage the hazardous
waste generated at a dry cleaning facility, liability for the waste does not
end when it leaves the cleaner's site. It is still the cleaner's responsibility
to ensure that the hazardous waste is properly managed.
Identification numbers
U.S. EPA ID numbers are required of all LQGs and SQGs. They are voluntary for
CESQGs, although some commercial treatment, storage and disposal facilities require
all customers to obtain them, independent of size. Notification forms and booklets
may be obtained by calling Ohio EPA, Division of Hazardous Waste Management.
Transportation Department requirements
Before sending hazardous waste off-site, dry cleaners must label, package, mark
and placard containers in accordance with Transportation Department regulations.
Please call the Public Utilities Commission of Ohio, Transportation Department,
if you have any questions regarding these requirements.
Step 5: Develop a personnel training program
Dry cleaners that are SQGs must ensure that their employees are thoroughly familiar
with proper waste handling and emergency procedures relevant to their job duties.
Step 6: Emergency Procedures
A SQG must have at least one employee either on the premises or on call at all
times designated as the emergency coordinator. The emergency coordinator or his
designee must respond to any emergencies that arise.
The following information must be posted next to a telephone which is available to all employees who handle hazardous waste and which is capable of contacting outside assistance:
For more information, contact Ohio EPA, Division of Hazardous Waste Management.
Figure 2 - Frequently found hazardous waste violations
|
Figure 3 - Serious hazardous waste violations
|
In September 1993, U.S. EPA issued national regulations (National Emission Standards for Hazardous Air Pollutants, or NESHAPs) to control air emissions of perc from dry cleaners. This regulation affects all dry cleaners that use perc, in both transfer and dry-to-dry machines.
Step 1: Determine classification
How a particular dry cleaner is affected depends on the type of machinery used
and the amount of perc used. Figure 4 shows how dry cleaners are classified.
| Figure 4 - Classification of dry cleaners based on perc usage | |||
|---|---|---|---|
| Dry cleaners with: | Small Area Source consuming less than: | Large Area Source consuming between: | Major Sources consuming more than: |
| Only dry-to-dry machines | 140 gallons perc/year | 140-2,100 gallons perc/year | 2,100 gallons perc/year |
| Only transfer machines | 200 gallons perc/year | 200-1,800 gallons perc/year | 1,800 gallons perc/year |
| Both dry-to-dry and transfer machines | 140 gallons perc/year | 140-1,800 gallons perc/year | 1,800 gallons perc/year |
Small dry cleaners do not need to install perc vapor recovery systems on "existing" machines, but must comply with the following regulations:
At larger dry cleaners, "existing" dry cleaning machines must be equipped with a refrigerated condenser (or a carbon adsorber if it was in place before September 22, 1993). Existing large sources must comply with all of the above requirements in addition to the following:
IMPORTANT: Dry cleaners with transfer systems must use separate condenser coils for controlling the perc air streams from the dryer/reclaimer and washer.
Major source dry cleaners that have a transfer machine must install a room enclosure around each transfer machine and vent the room enclosure to a carbon adsorber. Room enclosures cannot be vented to refrigerated condensers.
| Figure 5 - Requirements for Dry cleaning Facilities | ||||
|---|---|---|---|---|
| Applicability | Small Area Sources | Large Area Sources | Major Sources | |
| Process Vent Controls | ||||
| Existing Facilities | None | Refrigerated condenser, existing carbon absorbers can remain in place | ||
| New Facilities | Refrigerated condenser | Refrigerated condenser followed by small carbon absorber | ||
| Fugitive Controls | ||||
| Existing Facilities | Sealed containers, leak detection/repair | Room enclosure, sealed containers, leak detection/repair | ||
| New Facilities | No new transfer systems, sealed containers, leak detection/repair | |||
| Monitoring | ||||
| Existing Facilities | None | Meet parameters set for refregerated condensers and carbon absorbers | ||
| New Facilities | Meet parameters set for refregerated condensers and carbon absorbers | |||
| Inspections | ||||
| All Facilities | Biweekly | Weekly | ||
Step 3: Pollution prevention
The regulation requires all perc dry cleaners, regardless of size, to incorporate
the following pollution prevention steps:
Reporting and compliance
All perc dry cleaners must comply with the pollution prevention requirements
now.
Each facility is to submit a report to EPA by June 18, 1994, stating how it is complying with the EPA pollution prevention requirements (forms are available). All new facilities must comply upon start-up with all requirements and submit a compliance report within 30 days after start-up. This compliance report is submitted to EPA one time, and it is not required annually. However, a report must be submitted to EPA whenever any facility undergoes a change, such as an increase in the amount of perc purchased annually or the purchase of new equipment.
Perc vapor recovery systems (refrigerated condensers and carbon adsorbers) are not required until September 22, 1996, for existing machines. However, all new machines must be equipped with these systems upon start-up.
Refrigerated condensers must cool the perc vapor in the machine down to 45 degrees F or less at the end of the dry cleaning cycle. Any carbon adsorbers must not release perc in amounts over 100 parts per million of perc from a stack. Carbon adsorber test kits are available through dry cleaning trade associations and vendors. The carbon adsorber test is not required for existing machines until September 22, 1996. However, if a facility chooses to submit a compliance report to EPA before this date, it is required to start testing immediately. This test is required weekly for facilities that use carbon adsorbers for control requirement compliance.
For more information, contact Ohio EPA, Division of Air Pollution Control.
Surface water
Dry cleaners can generate wastewater, such as the solvent-contaminated wastewater
from water separators. Dry cleaners may have to respond to certain wastewater
regulations and requirements, based on factors specific to their operations.
Wastewater requirements include:
In order to determine their permitting requirements, it is important for dry cleaners to determine where their wastewater goes. Most dry cleaners with water supplied by a local water utility will discharge their sanitary wastewater from toilets and sinks, and process wastewater such as separator water, to a sanitary sewer system. This wastewater flows to a treatment plant. After treating the wastewater, the treatment plant discharges the treated water into a river, lake, stream or other water body.
Sources of wastewater can be determined by a walk-through of the dry cleaning facility. Special attention should be given to equipment and processes that use water or generate wastewater. A master plumbing diagram will show sanitary sewer lines and storm sewer piping. Additionally, evidence of flowing water may be seen outside the building. Dry cleaners should look for water flowing directly onto the ground from a pipe or other structure, or water flowing from a pipe into a creek, stream, river, pond or other water body.
Wastewater discharged to a treatment plant
Dry cleaners that discharge non-sanitary wastewater (separator water or other
process-related wastewater from sources other than toilets and bathroom sinks)
are required to obtain a discharge permit or letter of authorization from the
local treatment plant or from Ohio EPA. This notification is required even if
the volume of water or contamination is very low.
Step 1: Determine wastewaters generated
Identify the amount (gallons per day) of each of the various wastewaters generated
and develop a brief description of the concentration of pollutants (such as perc)
expected to be present in the wastewaters.
Treatment plants cannot effectively treat all types of wastewater, and are typically designed to treat only sanitary or domestic discharges. Each treatment plant has specific limits on the type and amount of pollutants that it is able to accept. These limits are based on the following:
Step 2: Notify the local treatment plant
The most efficient method of contacting a local treatment plant is through a
letter that identifies a dry cleaning operation and its associated discharge.
A dry cleaner can identify the appropriate person to receive this letter by inquiring
within the utility that issues its water bill, or by placing a call to the city
or town government office, or department of public works.
Step 3: Notify Ohio EPA
Dry cleaners should contact Ohio EPA, Division of Surface Water, Pretreatment
Unit, to determine if indirect discharge permits or permit by rule requirements
apply. In some communities, the local treatment plant has been given authority
by Ohio EPA to issue permits and to directly regulate wastewater discharges.
In these situations, dry cleaners should contact the local authority.
Normally, dry cleaners are viewed as small dischargers, and as such are not required to complete extensive discharge applications for indirect discharge permits, which are reserved for "significant industrial users." Significant industrial users are defined as facilities that discharge 25,000 gallons per day or more of process wastewater, or have the potential to disrupt local treatment plant operations, or are specifically regulated as a categorical industry by U.S. EPA. Currently, dry cleaners are not regulated as a categorical industry. However, dry cleaners should contact both Ohio EPA and local treatment plant authorities to determine what requirements may apply to them.
In addition, dry cleaners may be required to obtain a "permit to install" from Ohio EPA or a local delegated authority for dry cleaning equipment with wastewater discharges. Contact Ohio EPA, Division of Surface Water, Pretreatment Unit, for permit to install requirements.
Wastewater discharged to a creek, river or other body of water
When tracking their wastewaters, dry cleaners should confirm that all wastewater
proceeds directly to the treatment plant. If the wastewater is discharged from
the facility directly to a ditch, stream, river or other water body, or to a
septic system or storage well, additional regulations may apply.
Any wastewater (excluding storm water) from dry cleaning operations that is discharged directly into a storm sewer, creek, river, stream, pond, lake, ditch or other land or water body requires a National Pollutant Discharge Elimination System (NPDES) permit from Ohio EPA. (Note: NPDES permits are not required for water discharges of air conditioner condensate, springs, fire fighting or sprinkler runoff.)
Dry cleaners should attempt to divert wastewater discharges from a river or stream into a local treatment plant system to avoid this permitting requirement. Dry cleaners should do the following to help prevent direct discharges:
Ground water
Not all wastewater drains to a wastewater treatment plant - some dry cleaners
may be discharging wastewater to a disposal well or septic system. Dry cleaners
using disposal wells or septic systems to discharge waste fluids and residues
are actually operating Class V injection wells, which are subject to regulation
by Ohio EPA's Division of Drinking and Ground Waters, Underground Injection Control
Unit. Industrial Disposal Wells (5W20), one category of Class V injection wells,
are defined as wells or septic systems which receive or have the potential to
receive industrial or commercial fluids, wastes or wastewater.
Step 1: Determine if well is a Class V injection well
Class V injection wells generally inject fluids into or above an underground
source of drinking water and are frequently located in areas not served by a
sanitary sewer system, or where sewer systems are inadequate.
Underground Injection Control (UIC) regulations prohibit any underground injection,
except as authorized by permit or rule issued under Chapter 3745-34
of the Ohio Administrative Code (OAC).
To protect Ohio's underground sources of drinking water, owners or operators are prohibited from constructing, operating, maintaining, converting, plugging, or abandoning wells, or conducting any other injection activity that allows the movement of fluid containing any contaminant into an underground source of drinking water if the presence of the contaminant may cause a violation of primary drinking water regulation under OAC Chapter 3745-81 or may otherwise adversely affect the health of persons.
If at any time the director of Ohio EPA learns that a Class V well may cause a violation of primary drinking water regulations, he or she shall:
Step 2: Notification
UIC regulations established in 1984 require owners and operators of Class V wells
to notify the director of Ohio EPA of the existence of any Class V well and provide
the following information no later than November 9, 1985:
Step 3: Best management practices
U.S. EPA has developed fact sheets which identify best management practices for
protecting ground water for dry cleaners using shallow industrial waste disposal
wells. These address well closure, alternative disposal methods and pollution
prevention. These practices are recommendations only. To request copies, for
further information, to submit Class V inventory information or to request Class
V permit applications, please contact Ohio EPA, Division of Drinking and Ground
Waters, UIC Unit.
Case study number oneA drycleaning facility utilized three transfer cleaning machines and four drying units with a total capacity of 155 pounds. In advance of Clean Air Act deadlines, it replaced all these machines with three new closed-loop dry-to-dry machines with a combined capacity of 160 pounds. All three new machines included improved cartridges and systems for recycling perc.The largest machine utilized a spin disk to enhance its recycling system and reduce the need for disposable cartridges. With the old machinery, the dry cleaner purchased 500 gallons of perc per month. With the new machinery the company used a total of 50 gallons of perc over a four month period, resulting in a monthly savings of over 480 gallons of solvent. This saves $1,950 per month through the reduced purchases of solvent. The company's hazardous waste generation also has been greatly reduced, since fewer cartridges have to bedisposed. Its hazardous waste disposal cost have been reduced by two-thirds, from $1,500 per month to $500 per month. The capital cost for this project was $150,000. The payback period, based on reduced purchasing and hazardous waste disposal, is fouryears. In the first three years after the equipment was installed, 75 percent of the investment has already been recouped. The company has also reported a 20 percent increase in quallity, measured by fewer returns for recleaning. (Delaware Department of Natural Resources and Environmental Control, no date) |
Pollution Prevention
It has been estimated that over three quarters of the perc used at a dry cleaning
facility can be lost to the atmosphere through emissions. A significant amount
of perc also can be lost as hazardous waste (Source Reduction Research Partnership,
June). These emissions and wastes represent both a considerable loss of valuable
raw material and generation of pollutants.
The best way to reduce pollution, wastes or emissions is to prevent them in the first place. Pollution prevention is the use of source reduction techniques to reduce risk to public health, safety, welfare and the environment. It also includes recycling, as a second preference, to achieve these same goals. It avoids the transfer of wastes and/or pollutants across different environmental media (land, air and water), and addresses all types of waste and environmental releases to all of these media.
Source reduction techniques are any efforts to reduce, at the source, the quantity of waste generated, toxic chemical use, or any release into the environment. It includes activities such as process modifications, good operating and management practices, increases in the efficiency of machinery and recycling within a process.
Some pollution prevention activities are required for dry cleaners by the air regulations discussed previously in this document. Others are voluntary activities. In addition to obvious environmental and human safety benefits, pollution prevention can also potentially reduce liability and enhance a company's image. Economic incentives can be significant, depending on the nature of the processes and the competitiveness of the business environment.
Perhaps most important, in light of the previous discussion of the environmental regulations facing dry cleaners, pollution prevention may help reduce a dry cleaner's regulatory burden. For example, a dry cleaner that is classified as a LQG may be able to reduce its hazardous waste generation enough to be able to reclassify itself as a SQG or a CESQG. Among other things, this would allow the dry cleaner to increase the amount of time hazardous waste is stored on-site, and release it from the requirement to prepare annual hazardous waste generator reports.
Pollution prevention at dry cleaning facilities involves good housekeeping practices to minimize losses of solvents in liquid and vapor form, and also modifications to processes, equipment and operating practices. Options range from easily implemented, low cost improvements to more significant changes to equipment and operations. See Figure 6 for examples of pollution prevention activities.
Some of the more easily implemented changes include improved operating practices, inventory control and equipment maintenance. The most significant changes obtainable through readily available technology include equipment upgrades, such as changing from a transfer machine to a dry-to-dry or closed-loop dry-to-dry machine. These machines are described earlier in this document.
A dry cleaner can strategically address pollution prevention by first identifying all waste streams and emissions, determining their sources, and then investigating which changes will be most feasible and effective. For more information regarding the development of a pollution prevention program for all facility operations, contact Ohio EPA, Office of Pollution Prevention, for a copy of the four-page fact sheet, "Pollution Prevention - Getting Started," or the longer document, the "Ohio Pollution Prevention and Waste Minimization Planning Guidance Manual."
The most advanced pollution prevention options preclude the use of organic solvents as the primary cleaning agent. One such technology is multi-process wet cleaning. This uses labor-intensive cleaning techniques and high-tech washing and drying machines that use soap and water to clean clothes.
This cleaning customizes cleaning for each garment, beginning with an inspection of each garment for fabric type, construction, dirt and stains. A garment may be spot cleaned, steamed, and washed, or some combination of those processes, or cleaned in a washing machine that carefully regulates water temperature and agitation. Drying can be accomplished by drying cabinets, computer-controlled dryers or other similar means. Finally, garments are pressed or otherwise finished with techniques similar to those used by dry cleaners (Center for Neighborhood Technology, no date).
One common misperception is that wet cleaning does not actually clean the garments, but simply removes isolated spots. Wet cleaning actually includes a variety of cleaning technologies, and is specifically tailored for each garment, providing varying levels of cleanliness based upon the requirements of each particular garment.
Preliminary testing indicates that owners of garments cleaned by both wet cleaning and dry cleaning rate wet cleaned clothes as equal to or better than dry cleaned clothes. Tests have also shown that wet cleaning can give owners of dry cleaning establishments a slight economics advantage, due to lower cost of start-up capital, supplies, equipment and hazardous waste disposal (Center for Neighborhood Technology, no date).
| Figure 6 - Examples of pollution prevention opportunities for dry cleaners | |
|---|---|
| Improved operating practices | Conduct transfer of solvent-saturated clothes from washer to dryer as quickly as possible. Close dryer door immediately upon completion of transfer. Clean the filters that precede carbon filters weekly. Clean lint screens to avoid clogging fans and condenser. Open button trap and lint baskets only long enough to clean. Check baffle assembly in cleaning machine biweekly. Use closed, lablled containers for collection and storage of recovered or new solvent. Size loads correctly - do not overload or underload machines. |
| Inventory control | Buy only what you need, and organize shelves so that old materials are used first. Inspect material upon delivery and returnany that are unacceptable to suppliers. |
| Equipment maintenance | Inspect the following weekly for leaks: hose connections,unions, couplings and valves; machine door gaskets and seating; filter head gasket and seating; pumps; solvent base tanks and solvent and waste storage containers; water separators; filter sludge recovery; distillation units; diverter valves; and cartidge filters. Repair all leaks promptly. Replace seals regularly on dryer deodorizer and aeration valves. Replace door gasket on button trap. Replace gasket around cleaning machine door or tighten enclosure. Secure hose connections and couplings. Clean lint buildup on cooling condenser coils weekly. Use a hamper or room enclosure of impermeable construction to reduce solvent release during transfer. |
| Equipment modification | Place washer and dryer close toghather to minimize solvent loss during transfer. Replace the cartridge filters with spin disk filters that can be cleaned without opening. This will produce fewer fugitive emission and less hazardous waste. Install distillation equipment where the still bottoms can be removed without opening the still to reduce the waste streaam. Use carbon absorber that is regenerated with hot air stripping rather than stteam stripping. This reduces the waste stream. Use double carbon wastewater treatment devices to clean up perc-contaminated wastewaters, and recycle the treated wastewater to the process boiler. |
| Chemical substitutions | Alternative petroleum solvents are being developed with higher flash points to reduce the fire hazard. Alternative petroleum solvents are being developed with lower VOC contents. |
| Major equipment upgrades | Add a refrigerated condenser to the machine for primary control, and a carbbon absorber for secondary control, and recycle solvent. Replace a transfer machine with a dry-to-dry machine. Upgrade a dry-to-dry machine with additional control equipment such as a spill container that will catch and recycle solvent spills from the machine. Replace current machine with dry-to-dry non-vented machine that contains an integral refrigerated condenser and an integral carbone absorber. |
| Technological innovation | The majority of the hazardous waste is generated by the carbon absorbers. Several new technologies are being developed that use a polymer surface for absorbing the solvent vapor. The surface can be regenerated by heating and unlike carbon, does not need to be replaced, thus reducing hazardous waste. Multiprocess wet cleaning doen not use organic solvent as the primary solvent. Both ultrasonic cleaning and a cleaning method using liquid carbone dioxide are under development. |
| (Ohio EPA, 1993; U.S. EPA, 1995; Texas Natural Resource Consevation Commission, no date) | |
Case study number twoThis dry cleaner provides industrial laundry services using stoddard solvent. Prior to the implementation of a secondary still for distilling waste solvent, this LQG's (Large Quantity Generator) primary hazardous waste stream was a stoddard solvent still bottom. This waste, nearly 85 tons in 1994, was a characteristic hazardous waste due to ignitability.Installation of the equipment was accompanied by installation of pumps and piping designed to eliminate worker contact with the still bottom and associated material. The still bottoms from the primary still are pumped driectly to the new still, where they undergo a second vacuum distillation while being continuously stirred. The reclaimed solvent (about 25 percent of the primary still bottoms) is pumped directly into a storage tank, and can be reused in the dry cleaning process as is. The remaining oily residual is also pumped directly into a storage tank. Its flash point is approximately177 degrees, so it is no longer considered a hazardous waste. This project has nearly eliminated hazardous waste generation. The reduction in fugitive air emissions (due primarily to the pumps and lines installed, reducing exposure of material to air) have not been measured. This project cost approximately $200,000 to implement. Cost savings will be achieved through reduced raw material cost and reduced waste management cost. The facility expects to save approximately $3,000 in solvent purchases and $2,000 in waste management cost annually. These values do not take into account savings achieved trough reduced paper work, reduced labor or other areas that may have benefited financially trough the implementation of this project. The most significant benefit cited by the facility was the potectial to be reclassified at a lower level of hazardous waste generation (Ohio EPA, 1995). |
Division of Drinking and Ground Waters
Underground Injection Control Unit
(614) 644-2752
Division of Hazardous Waste Management
Technical Support Unit
(614) 644-2934
Division of Surface Water
Industrial Permitting Unit
(614) 644-2037
Pretreatment Unit
(614) 644-2021
Office of Pollution Prevention
(614) 644-3469
Who to call at the Public Utilities Commission of Ohio:
Transportation Department
(614) 466-0409
References
Center for Neighborhood Technology, no date. Wet cleaning : An alternative to dry
cleaning that is safe for you, your clothes, and your cleaner. Center for Neighborhood
Technology. Chicago, Illinois.
Delaware Department of Natural Resources and Environmental Control, no date. Pollution Prevention success story: Capital Cleaners. Delaware Department of Natural Resources and Environmental Control, Pollution Prevention Program. Delaware.
Ohio Environmental Protection Agency (Ohio EPA). August, 1993. Managing and reducing hazardous waste from dry cleaning. Ohio Environmental Protection Agency, Division of Hazardous Waste Management. Columbus, Ohio.
Ohio Environmental Protection Agency (Ohio EPA). September, 1995. Pollution prevention in Ohio environmental enforcement settlements - analysis and update. Ohio Environmental Protection Agency, Office of Pollution Prevention. Columbus, Ohio.
Printing Industry of Ohio. 1995. A self help guide to environmentally sound printing operations. Printing Industry of Ohio.
Source Reduction Research Partnership. 1991. Source rediction of chlorinated solvents: Dry cleanig of fabrics. California Department of Toxic Substances Control, Alternative Technology Division. Sacramento, California.
Texas Natural Resource Conservation Commission. No date. An Environmental guide for Texas dry cleaner: An overview of pollution prevention, rules and permits (first edition). Texas Natural Resource Conservation Commission, Small Business Technical Assistance Program. Austin, Texas.
University of Tennessee Center for Industrial Services (CIS). No date. Clearing the air on clean air: Strategies for perc dry cleaners. University of Tennessee Center for Industrial Services, Waste Reduction Assistance Program. Nashville, Tennessee.
U.S. Environmental Protection Agency (U.S. EPA). September, 1995. Profile of the dry cleaning industry. EPA 310-R-95-001. U.S. Environmental Protection Agency, Office of Enforcement and Compliance Assurance. Washington, DC.